NDTitans offers professional testing services for clients to ensure that testing with advanced systems is performed correctly, e.g. testing grout injection of cable ducts or joints between elements, voids below industrial floors, testing for safe and early loading of structures, and testing for evaluating the remaining service life or load carrying capacity.

AVAILABLE TEST SYSTEMS

▪ AVA (Air Void Analyzer)

▪ AP TempSim

▪ Auto-Shrink

▪ BOND-TEST

▪ Corecase

▪ Coma-Meter

▪ CoverMaster

▪ Drones for visual inspection.

▪ DOCter Impact-Echo

▪ GalvaPulse (corrosion rate, potentials and electrical resistance of the cover layer)

▪ GWT (Germann ́s Water Permeation Test) 

▪ GPR (Ground Penetrating Radar)

▪ Heat Box▪ ICAR Rheometer

▪ MIRA Tomography (ultrasonic echo) 

▪ MERLIN Bulk Electrical Conductivity Test

▪ s ́MASH Impulse Response

▪ Pullout test, LOK-TEST, new structures

▪ Pullout test, CAPO-TEST, existing structures 

▪ PROOVE ́it Rapid Chloride Permeability Test 

▪ PIT (Pile Integrity Test)

▪ Rainbow Indicator for carbonation

▪ RapidAir (air-void structure) 

▪ RCT (Rapid Chloride Test)

▪ RAT (Rapid Alkali Test)

▪ TMS (Temperatures, Maturity, Strength)

▪ UPV (Ultrasonic Pulse Velocity)

Please visit Germann.org for additional information

PROPERTIES MEASURED

1. FRESH CONCRETE AND MIXTURE EVALUATION

1.1  Rheology

1.2  Chloride content of concrete and its components

1.3  Resistance to chloride penetration

1.4  ASR, reactivity of sand and aggregates

1.5  Alkali content (equiv . Na2O/m3) for evaluation of the potential risk of ASR

1.6  Adiabatic heat development

1.7  Temperature simulation

1.8  Air-void structure (spacing factor and specific surface)

1.9  Autogenous shrinkage of the mortar fraction

2. HARDENING STRUCTURES

2.1  Temperature recording

2.2  Maturity measurement

2.3  In-Place strength for safe and early loading

2.4  Cover layer quality

2.5  Curing

2.6  Grout injection quality e.g. in cable ducts and joints

2.7  Cracking

2.8  Crack depth

3. FINISHED STRUCTURES

3.1  Strength for QA/QC

3.2  Bond strength

3.3  Tightness of casting/construction joints

3.4  Water permeability

3.5  Chloride content

3.6  Resistance to chloride penetration of the cover layer

3.7  Reinforcement location

3.8  Petrography

4. EVALUATION OF EXISTING STRUCTURES

4.1  Thickness of elements

4.2  Chloride ion profiling

4.3  Depth of carbonation

4.4  Corrosion activity

4.5  Corrosion mitigation

4.6  Remaining alkali content (equiv . Na2O/m3)

4.7  Integrity of cable duct injection and corrosion of strands

4.8  Voids, e.g. behind slabs, industrial floors and tunnel lining elements

4.9  Membrane failure

4.10  Strength for structural capacity

4.11  Cracking evaluation

4.12  Water tightness of joints

4.13  Air-Void structure

4.14  Crack movement

4.15  Bond strength

4.16  Internal defects

4.17  Delamination detection

4.18  Asphalt overlay de-bonding of bridge slabs

4.19  Curling

4.20  ASR

4.21  Reinforcement location and size

4.22  Pile integrity

4.23  Removal of cores